Professional Engineering Services

1540 Baxley Road – Commercial Lot, Middleburg, FL – Geotechnical Exploration
  • Location Middleburg, Clay County, FL
  • Owner Dr. Rajesh K. Shetty (c/o Sodl & Ingram PLLC)
  • Markets Commercial, Geotechnical Engineering
  • Services Geotechnical Exploration, Subsurface Investigation, Laboratory Testing, Foundation & Pavement Recommendations

Project Description

NicNevol Engineering Services conducted a geotechnical exploration and evaluation for a commercially zoned lot located at 1540 Baxley Road in Middleburg, FL. The study assessed subsurface soil and groundwater conditions to support the design of proposed retail buildings, parking areas, and a stormwater retention pond. :contentReference[oaicite:1]{index=1}

Field work included five (5) hand auger borings to ~6 ft depth and three (3) Standard Penetration Test (SPT) borings to ~25 ft depth. Groundwater was encountered at approximately 3.0–3.5 ft below grade. Subsurface conditions revealed surficial sands (SP) underlain by clayey sands (SC), clays (CH), silty sands (SM), and shallow limestone at 18–25 ft depth. :contentReference[oaicite:2]{index=2}

Recommendations included undercutting unsuitable clays, replacing with select structural fill or No. 57 stone, compacting to 95% Modified Proctor, and implementing groundwater and surface-water control during construction. Pavement design parameters included an 8 in. limerock base (LBR 100) with a 1.5–2 in. asphalt surface. :contentReference[oaicite:3]{index=3}

NicNevol Responsibilities

  • Conducting hand auger and SPT borings.
  • Performing soil classification and laboratory testing.
  • Evaluating subsurface soil and groundwater conditions.
  • Providing foundation, slab, and pavement design parameters.
  • Preparing recommendations for excavation, fill, and compaction.
  • Delivering the final geotechnical report with design guidance for retail site development.

Project Highlights

  • Client: Dr. Rajesh K. Shetty (c/o Sodl & Ingram PLLC).
  • Commercial lot development with retail buildings, parking, and stormwater pond.
  • Field program: 5 hand auger borings (6 ft) + 3 SPT borings (25 ft).
  • Subsurface profile: sands (SP), clayey sands (SC), clays (CH), silty sands (SM), shallow limestone at 18–25 ft.
  • Groundwater: ~3.0–3.5 ft below surface.
  • Pavement: 8 in. limerock base (LBR 100) + 1.5–2 in. asphalt surface.
  • Recommendations: site clearing, undercut clays, replace with structural fill, compact to 95% Modified Proctor, groundwater/surface water control.